Add to Cart
Product name: WEIGUANG Motor Coolroom Evaporator Refrigeration Equipment
EC SERIES COMMERCIAL DUAL-DISCHARGE UNIT COOLERS
1. Product description:
EC series commercial dual-discharge air coolers adopt ultra-thin structure design, with air inlet at the bottom and air outlet at the two sides. The product has small installation space and is mainly used in manned processing rooms or cold room with small height size .
This series of products have the following characteristics:
● Casing: Al-Mg alloy sheet with silver powder coating (RAL7001) , it has strong anti-corrosion property and light weight.
● Evaporator end plate adopts aluminum plate, effectively protect copper tube, reduce weight.
● Double water plate design: the outer water plate with hinge structure design, convenient operation; The inner water tray adopts the flume structure of aluminum plate. The condensed water or defrosted water is directly discharged into the outlet of the outer water tray through the inner water tray.
● Coil:copper pipe φ12, spacing 38.1×33, triangle arrangement, heat transfer efficiency is high.
● Corrugated aluminum fins with hydrophilic film, fin spacing of 4.0 and 6.0mm to meet the different temperature requirements of cold storage.
● Fans:external rotor fan, fan specification φ350, working temperature -30~60℃, the number of fans 1 to 4. With high speed and low speed design, can meet different noise requirements.
● Defrosting:standard electric heating defrosting, stainless steel heating pipe are distributed on the coil tube fin and inner water plate, has a good defrosting effect.
● IP65 grade waterproof junction box and waterproof connector, the fan and heating pipe adopt independent wire box ,with better waterproof effect, high reliability.
● The outlet of the air cooler is equipped with schrader alve, which is convenient for users to detect pressure.
● Strict factory pressure test, test pressure 23bar.
● Expansion valve can be pre-installed according to customer requirements.
● It can meet refrigerant for R404A,R507A,R448A,R449A,R134a,R22 etc.
2. Standard configuration and options:
Parts | Configuration | Parts | Configuration | ||
Casing | Al-Mg alloy sheet with powder coating | ● | Defrosting | Air defrosting | ○ |
sheet with powder coating | ○ | Electric heating pipe | ● | ||
Galvanized sheet with powder coating | ○ | Hot gas | ○ | ||
Stainless steel plate | ○ | Expansion valve | ○ | ||
Fan | WEIGUANG motor | ● | Drainpipe hot wire | ○ | |
EBM motor | ○ | Wind duct heating belt | × | ||
The wind bucket motor | × | ||||
Fin | Aluminum fins | ○ | |||
Hydrophilic aluminum fins | ● |
●:Standard;○:Options;×:Do not choose
3. Technical data sheet:
3.1 Standard speed fans (1420rpm):
3.1.1 Fin spacing 4.0mm
Model | Capacity/R404A (KW) | Surface | Tube volume | Airflow | Airthrow | Connection pipe | Weight | |||
Tc=0℃ ΔΤ=8K | Tc=10℃ ΔΤ=10K | m2 | dm3 | m3/h | m | Inlet | Outlet | Drain | kg | |
EC351/CLN-ET | 3.2 | 4.7 | 13.1 | 2.5 | 2200 | 6 | φ12 | φ22 | G1” | 31 |
EC351/DLN-ET | 4.0 | 5.8 | 17.5 | 3.4 | 2000 | 6 | φ12 | φ22 | G1” | 33 |
EC352/CLN-ET | 6.5 | 9.5 | 26.3 | 4.7 | 4400 | 8 | φ12 | φ22 | G1” | 51 |
EC352/DLN-ET | 8.0 | 11.7 | 35.0 | 6.3 | 4000 | 8 | φ12 | φ22 | G1” | 55 |
EC353/CLN-ET | 9.8 | 14.4 | 39.4 | 6.9 | 6600 | 9 | φ16 | φ28 | G1” | 73 |
EC353/DLN-ET | 12.0 | 17.6 | 52.5 | 9.2 | 6000 | 9 | φ16 | φ28 | G1” | 79 |
EC354/CLN-ET | 13.1 | 19.2 | 52.5 | 9.1 | 8800 | 10 | φ16 | φ28 | G1” | 93 |
EC354/DLN-ET | 16.1 | 23.6 | 70.0 | 12.2 | 8000 | 10 | φ16 | φ35 | G1” | 100 |
1.In the table ,Tc is cold room temperature, ΔΤ is difference between cold room temp. and evaporation temp.
2. The airthrow is 0.5m/s air arrived distance at ambient temperature.
3. For cooling capacity of other working conditions, please refer to the correction coefficient.
3.1.2 Fin spacing 6.0mm
Model | Capacity/R404A (KW) | Surface | Tube volume | Airflow | Airthrow | Connection pipe | Weight | |||
Tc=0℃ ΔΤ=8K | Tc=-18℃ ΔΤ=7K | m2 | dm3 | m3/h | m | Inlet | Outlet | Drain | kg | |
EC351/CDN-ET | 2.5 | 2.0 | 9.0 | 2.5 | 2350 | 6 | φ12 | φ22 | G1” | 30 |
EC351/DDN-ET | 3.1 | 2.4 | 12.0 | 3.4 | 2200 | 6 | φ12 | φ22 | G1” | 32 |
EC352/CDN-ET | 5.1 | 4.1 | 18.1 | 4.7 | 4700 | 8 | φ12 | φ22 | G1” | 50 |
EC352/DDN-ET | 6.3 | 5.0 | 24.1 | 6.3 | 4400 | 8 | φ12 | φ22 | G1” | 53 |
EC353/CDN-ET | 7.6 | 6.0 | 27.1 | 6.9 | 7050 | 9 | φ16 | φ28 | G1” | 71 |
EC353/DDN-ET | 9.4 | 7.5 | 36.1 | 9.2 | 6600 | 9 | φ16 | φ28 | G1” | 76 |
EC354/CDN-ET | 10.1 | 8.0 | 36.1 | 9.1 | 9400 | 10 | φ16 | φ28 | G1” | 91 |
EC354/DDN-ET | 12.5 | 10.0 | 48.2 | 12.2 | 8800 | 10 | φ16 | φ35 | G1” | 97 |
1.In the table ,Tc is cold room temperature, ΔΤ is difference between cold room temp. and evaporation temp.
2. The airthrow is 0.5m/s air arrived distance at ambient temperature.
3. For cooling capacity of other working conditions, please refer to the correction coefficient.
3.2 Low speed fans(920rpm):
3.2.1 Fin spacing 4.0mm
Model | Capacity/R404A (KW) | Surface | Tube volume | Airflow | Airthrow | Connection pipe | Weight | |||
Tc=0℃ ΔΤ=8K | Tc=10℃ ΔΤ=10K | m2 | dm3 | m3/h | m | Inlet | Outlet | Drain | kg | |
EC351/CLS-ET | 2.4 | 3.2 | 13.1 | 2.5 | 1150 | 5 | φ12 | φ22 | G1” | 31 |
EC351/DLS-ET | 2.8 | 3.8 | 17.5 | 3.4 | 1300 | 5 | φ12 | φ22 | G1” | 33 |
EC352/CLS-ET | 4.7 | 6.6 | 26.3 | 4.7 | 2300 | 7 | φ12 | φ22 | G1” | 51 |
EC352/DLS-ET | 5.6 | 7.7 | 35.0 | 6.3 | 2600 | 7 | φ12 | φ22 | G1” | 55 |
EC353/CLS-ET | 7.1 | 9.8 | 39.4 | 6.9 | 3450 | 8 | φ16 | φ28 | G1” | 73 |
EC353/DLS-ET | 8.4 | 11.6 | 52.5 | 9.2 | 3900 | 8 | φ16 | φ28 | G1” | 79 |
EC354/CLS-ET | 9.5 | 13.0 | 52.5 | 9.1 | 4600 | 9 | φ16 | φ28 | G1” | 93 |
EC354/DLS-ET | 11.2 | 15.4 | 70.0 | 12.2 | 5200 | 9 | φ16 | φ35 | G1” | 100 |
1.In the table ,Tc is cold room temperature, ΔΤ is difference between cold room temp. and evaporation temp.
2. The airthrow is 0.5m/s air arrived distance at ambient temperature.
3. For cooling capacity of other working conditions, please refer to the correction coefficient.
3.2.2 Fin spacing 6.0mm
Model | Capacity/R404A (KW) | Surface | Tube volume | Airflow | Airthrow | Connection pipe | Weight | |||
Tc=0℃ ΔΤ=8K | Tc=-18℃ ΔΤ=7K | m2 | dm3 | m3/h | m | Inlet | Outlet | Drain | kg | |
EC351/CDS-ET | 2.0 | 1.6 | 9.0 | 2.5 | 1300 | 5 | φ12 | φ22 | G1” | 30 |
EC351/DDS-ET | 2.4 | 1.9 | 12.0 | 3.4 | 1450 | 5 | φ12 | φ22 | G1” | 32 |
EC352/CDS-ET | 4.2 | 3.3 | 18.1 | 4.7 | 2600 | 7 | φ12 | φ22 | G1” | 50 |
EC352/DDS-ET | 5.1 | 4.0 | 24.1 | 6.3 | 2900 | 7 | φ12 | φ22 | G1” | 53 |
EC353/CDS-ET | 6.2 | 5.0 | 27.1 | 6.9 | 3900 | 8 | φ16 | φ28 | G1” | 71 |
EC353/DDS-ET | 7.6 | 6.0 | 36.1 | 9.2 | 4350 | 8 | φ16 | φ28 | G1” | 76 |
EC354/CDS-ET | 8.3 | 6.6 | 36.1 | 9.1 | 5200 | 9 | φ16 | φ28 | G1” | 91 |
EC354/DDS-ET | 10.1 | 8.0 | 48.2 | 12.2 | 5800 | 9 | φ16 | φ35 | G1” | 97 |
1.In the table ,Tc is cold room temperature, ΔΤ is difference between cold room temp. and evaporation temp.
2. The airthrow is 0.5m/s air arrived distance at ambient temperature.
3. For cooling capacity of other working conditions, please refer to the correction coefficient.
4. Electrical parameter table:
Model | Fan motor | Electric defrosting | |||||
Voltage (V) | Power (W) | Current (A) | Speed (r/min) | Coil (KW) | Tray (KW) | Total (KW) | |
EC351/**N-ET | 380-3 | 165 | 0.43 | 1420 | 2×0.6 | 2×0.6 | 2.4 |
EC352/**N-ET | 380-3 | 330 | 0.86 | 1420 | 2×1.1 | 2×1.1 | 4.4 |
EC353/**N-ET | 380-3 | 495 | 1.29 | 1420 | 2×1.6 | 2×1.6 | 6.4 |
EC354/**N-ET | 380-3 | 660 | 1.72 | 1420 | 2×2.0 | 2×2.0 | 8.0 |
EC351/**S-ET | 380-3 | 80 | 0.32 | 920 | 2×0.6 | 2×0.6 | 2.4 |
EC352/**S-ET | 380-3 | 160 | 0.64 | 920 | 2×1.1 | 2×1.1 | 4.4 |
EC353/**S-ET | 380-3 | 240 | 0.96 | 920 | 2×1.6 | 2×1.6 | 6.4 |
EC354/**S-ET | 380-3 | 320 | 1.28 | 920 | 2×2.0 | 2×2.0 | 8.0 |
5.How to select correct evaparator:
Generally,Choose evaporator capacity=cold room cooling capacity *1.15
1.When the cold room temperature is around 0℃, select 4.5mm as fin space.
Evaporator choose=1.0*Q0
2.When the cold room temperature is around -18℃, select 6mm as fin space.
Evaparator choose=1.1*Q0
3.When the cold room temperature is around -25℃, select 9mm as fin space.
Evaparator choose=1.27*Q0
Remarks: The water defrost and hot gas defrost type are also optional.
Customized specification leave me message for details.
6.Want to know other related products?-click picture for detailed specification
7.How to assure quality? Any procedure?
Our QC department will make sure of each step
8.Do you factory?
We are factory established in 1995 and through 24years developed,welcomed by all our customers.Because of all your support now we are a big family of more than 300 people,covered 50000 square meters,and your supporting is very important of continuing our dream of eating fresh and healthy food.
9.Do you attend exhibition?
Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.
10.Why choose us
Professional:23 years focus one thing-refrigeration equipments
Material we use sufficient
Certificate:CE, ISO, and cetiifcate of producing special pressure equipment
11.Projects reference?
12.FAQ
1, Q:Where is your factory address?
A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.
2, Q: What is your package?
A: Our package comply to custom require not include original wood.
3, Q:What is your MOQ?
A: Ordinary products can order from 1 set.
4, Q: Can you offer sample?
A: Yes,we can offer sample.and cost and delivery at your charge.
5, Q:I can't find products on your list?
A: Please contact me directly.
6,Q:How can i confirm your factory?
A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.