ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD

Industrious,Profession,Cooperation,Innovation

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Coolroom Evaporator /

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

Contact Now
ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrGavin
Contact Now

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

Ask Latest Price
Video Channel
Brand Name :Kaideli
Model Number :EDG series
Certification :CE,ISO9001-2008
Place of Origin :China
MOQ :1 Piece
Price :$100.00 - $1,700.00/sets
Payment Terms :TT,LC,Western Union
Supply Ability :2000 Set/Sets per Month
Delivery Time :10-15 days
Packaging Details :Wood box packing
Applicable Industries :Hotels, Building Material Shops, Machinery Repair Shops, Food & Beverage Factory, Farms, Home Use, Retail, Food Shop, Construction works , Food & Beverage Shops
Showroom Location :Viet Nam, Philippines, Mexico, Thailand, Kazakhstan, Nigeria, Uzbekistan, Tajikistan
Video outgoing-inspection :Provided
Machinery Test Report :Provided
Type :Evaporator
Application :Refrigeration Parts
Warranty :1 Year
Color :Option (White,green,black)
Refrigerant :Optional
Brand :Kaideli
Fin space :4.5-12mm
Test :2.6Mpa
Cooling capacity :1.2kw--114kw
Voltage :220/380v
Package :Export wooden
Fin material :Aluminun
Usage :Freezer
After Warranty Service :Online support
Local Service Location :None
Marketing Type :New Product 2023
After-sales Service Provided :Video technical support, Field installation, commissioning and training, No after-sales service, Online support
Port :Ningbo/Shanghai/Guangzhou
Conditon :New
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product name: Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

EDG SERIES INDUSTRIAL DUAL-DISCHARGE GLYCOL UNIT COOLERS

1. Product description:

EDG series industrial air cooler adopts the structure of air inlet from the bottom and air outlet from the two sides., which are mainly used for cooling equipment in cold storage with glycol aqueous solution as the refrigerant. The low-temperature glycol aqueous solution circulates in the heat exchange tube of the cooling fan to absorb external heat, so as to achieve the purpose of reducing the storage temperature. EDG series of air coolers can be used in cold storage at 10℃, 0℃ and -18℃ respectively

This series of products have the following characteristics:

● Casing:high quality galvanized steel with silver powder coating (RAL7001) , it has strong anti-corrosion property; The outer water plate adopt hinge structure, convenient and quick operation.

● Evaporator end plate adopts aluminum plate, effectively protect copper tube, reduce weight.

● Double water plate design: the outer water plate adopts angular structure, smooth drainage, no drainage dead angle; The inner water tray adopts the flume structure of aluminum plate. The condensed water or defrosted water is directly discharged into the outlet of the outer water tray through the inner water tray.

● Coil:copper pipe φ15, tube spacing 50×50 square arrangement, heat transfer area is large, heat transfer temperature difference is small, fin frosting speed is slow.

● Corrugated aluminum fins with hydrophilic film, fin spacing of 4.0 , 6.0 and 9.0mm to meet the different temperature requirements of cold storage.

● Fan: high-power external rotor fan of blower, operating temperature -30℃~60℃; Fan specifications φ450,φ500, the formation of different specifications of the product series, users have more choices.

● Defrosting:standard electric heating defrosting, stainless steel heating pipe are distributed on the coil tube fin and inner water plate, has a good defrosting effect.

● IP65 grade waterproof junction box and waterproof connector, the fan and heating pipe adopt independent wire box ,with better waterproof effect, high reliability.

● Strict factory pressure test, test pressure 23bar.

2. Standard configuration and options:

Parts Configuration Parts Configuration
Casing Al-Mg alloy sheet with powder coating × Fin Aluminum fins
sheet with powder coating Hydrophilic aluminum fins
Galvanized sheet with powder coating Defrost Air defrosting
Stainless steel plate Electric heating pipe
Fan WEIGUANG motor Water ×
EBM motor Drainpipe hot wire
The wind bucket motor × Wind duct heating belt ×

●:Standard;○:Options;×:Do not choose.

3. Technical data sheet:

3.1 Fin spacing 4.0mm

Model

Glycol 25%

T1=-3, T2=2

Tr=10,RH85%

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capa. (KW)

Liquid Flow

(m3/h)

Capa. (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet drain kg
EDG451/DL-ET 7.4 1.4 4.2 1.3 35.0 4.8 4500 6 22 22 2-1" 73
EDG452/DL-ET 14.7 2.7 8.4 2.7 70.0 8.8 9000 8 28 28 2-1" 114
EDG453/DL-ET 22.1 4.1 12.6 4.0 105.0 12.9 13500 10 28 28 2-1.5" 155
EDG454/DL-ET 29.4 5.4 16.8 5.4 140.0 17.0 18000 12 35 35 2-1.5" 196
EDG501/DL-ET 10.5 1.9 5.8 1.9 52.5 6.8 6000 7 28 28 2-1" 89
EDG502/DL-ET 21.0 3.9 11.6 3.7 105.0 12.9 12000 9 28 28 2-1.5" 145
EDG503/DL-ET 31.5 5.8 17.3 5.5 157.5 19.0 18000 11 35 35 2-1.5" 201
EDG504/DL-ET 42.0 7.7 23.1 7.4 210.0 25.0 24000 13 35 35 2-1.5" 257

3.2 Fin spacing 6.0mm

Model

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Glycol 50%

T1=-28,T2=-25

Tr=-18,RH95%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capa. (KW)

Liquid Flow

(m3/h)

Capa. (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet Drain kg
EDG451/DD-ET 3.8 1.2 3.1 1.1 23.7 4.8 5000 6 22 22 2-1" 71
EDG452/DD-ET 7.6 2.4 6.2 2.2 47.5 8.8 10000 8 28 28 2-1" 110
EDG453/DD-ET 11.4 3.6 9.3 3.3 71.2 12.9 15000 10 28 28 2-1.5" 149
EDG454/DD-ET 15.2 4.9 12.3 4.3 94.9 17.0 20000 12 35 35 2-1.5" 188
EDG501/DD-ET 5.3 1.7 4.3 1.5 35.6 6.8 6300 7 28 28 2-1" 86
EDG502/DD-ET 10.7 3.4 8.5 3.0 71.2 12.9 12600 9 28 28 2-1.5" 139
EDG503/DD-ET 16.0 5.1 12.8 4.5 106.8 19.0 18900 11 35 35 2-1.5" 192
EDG504/DD-ET 21.4 6.9 17.1 6.0 142.4 25.0 25200 13 35 35 2-1.5" 246

3.3 Fin spacing 9.0mm

Model

Glycol 34%

T1=-10, T2=-7

Tr=0,RH85%

Glycol 50%

T1=-28,T2=-25

Tr=-18,RH95%

Surface

Tube

Volume

Airflow Airthrow Connect pipe Weight
Capa. (KW)

Liquid Flow

(m3/h)

Capa. (KW)

Liquid Flow

(m3/h)

m2 dm3 m3/h m Inlet Outlet Drain kg
EDG451/DJ-ET 3.1 1.0 2.6 0.9 16.2 4.8 5400 7 22 22 2-1" 71
EDG452/DJ-ET 6.2 2.0 5.2 1.8 32.5 8.8 10800 9 28 28 2-1" 109
EDG453/DJ-ET 9.3 3.0 7.8 2.7 48.7 12.9 16200 11 28 28 2-1.5" 148
EDG454/DJ-ET 12.4 4.0 10.4 3.6 65.0 17.0 21600 13 35 35 2-1.5" 186
EDG501/DJ-ET 4.4 1.4 3.7 1.3 24.6 6.8 6900 8 28 28 2-1" 85
EDG502/DJ-ET 8.8 2.8 7.3 2.6 48.7 12.9 13800 10 28 28 2-1.5" 138
EDG503/DJ-ET 13.2 4.2 11.0 3.9 73.1 19.0 20700 12 35 35 2-1.5" 190
EDG504/DJ-ET 17.8 5.7 14.6 5.1 97.5 25.0 27600 14 35 35 2-1.5" 243

In the table, T1 is the inlet temp. of ethylene glycol solution, T2 is the outlet temp., and Tr is the temp. of cold room.

4. Electrical parameter table:

Model Fan motor Electric defrosting
Voltage(V) Input(W) Current(A) Speed(r/min) Coil(KW) Tray(KW) Total(KW)
EDG451* 380-3 370 0.75 1380 4×0.6 2×0.6 3.6
EDG452* 380-3 740 1.5 1380 4×1.1 2×1.1 6.6
EDG453* 380-3 1110 2.25 1380 4×1.6 2×1.6 9.6
EDG454* 380-3 1480 3.0 1380 4×2.0 2×2.0 12.0
EDG501* 380-3 500 0.95 1380 4×0.8 2×0.8 4.8
EDG502* 380-3 1000 1.9 1380 4×1.6 2×1.6 9.6
EDG503* 380-3 1500 2.85 1380 4×2.3 2×2.3 13.8
EDG504* 380-3 2000 3.8 1380 4×3.0 2×3.0 18.0

5.How to select correct evaparator:

Generally,Choose evaporator capacity=cold room cooling capacity *1.15

1.When the cold room temperature is around 0℃, select 4.5mm as fin space.

Evaporator choose=1.0*Q0

2.When the cold room temperature is around -18℃, select 6mm as fin space.

Evaparator choose=1.1*Q0

3.When the cold room temperature is around -25℃, select 9mm as fin space.

Evaparator choose=1.27*Q0

Remarks: The water defrost and hot gas defrost type are also optional.

Customized specification leave me message for details.

6.Want to know other related products?-click picture for detailed specification

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

7.How to assure quality? Any procedure?

Our QC department will make sure of each step

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

8.Do you factory?
We are factory established in 1995 and through 24years developed,welcomed by all our customers.Because of all your support now we are a big family of more than 300 people,covered 50000 square meters,and your supporting is very important of continuing our dream of eating fresh and healthy food.

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

9.Do you attend exhibition?

Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

10.Why choose us

Professional:23 years focus one thing-refrigeration equipments

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

Material we use sufficient

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

Certificate:CE, ISO, and cetiifcate of producing special pressure equipment

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

11.Projects reference?

Air Defrosting Coolroom Evaporator Cold Room Outdoor Unit 23bar

12.FAQ

1, Q:Where is your factory address?

A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.

2, Q: What is your package?

A: Our package comply to custom require not include original wood.

3, Q:What is your MOQ?

A: Ordinary products can order from 1 set.

4, Q: Can you offer sample?

A: Yes,we can offer sample.and cost and delivery at your charge.

5, Q:I can't find products on your list?

A: Please contact me directly.

6,Q:How can i confirm your factory?

A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.

Inquiry Cart 0