ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD

Industrious,Profession,Cooperation,Innovation

Manufacturer from China
Verified Supplier
3 Years
Home / Products / Coolroom Evaporator /

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

Contact Now
ZHEJIANG KAIDI REFRIGERATION EQUIPMENT CO.,LTD
Visit Website
Province/State:zhejiang
Country/Region:china
Contact Person:MrGavin
Contact Now

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

Ask Latest Price
Video Channel
Brand Name :Kaideli
Model Number :EF series
Certification :CE,ISO9001-2008
Place of Origin :China
MOQ :1 Piece
Price :$100.00 - $1,700.00/sets
Payment Terms :TT,LC,Western Union
Supply Ability :2000 Set/Sets per Month
Delivery Time :10-15 days
Packaging Details :Wood box packing
Applicable Industries :Hotels, Building Material Shops, Machinery Repair Shops, Food & Beverage Factory, Farms, Home Use, Retail, Food Shop, Construction works , Food & Beverage Shops
Showroom Location :Viet Nam, Philippines, Mexico, Thailand, Kazakhstan, Nigeria, Uzbekistan, Tajikistan
Video outgoing-inspection :Provided
Machinery Test Report :Provided
Type :Evaporator
Application :Refrigeration Parts
Warranty :1 Year
Color :Option (White,green,black)
Refrigerant :Optional
Brand :Kaideli
Fin space :4.5-12mm
Test :2.6Mpa
Cooling capacity :1.2kw--114kw
Voltage :220/380v
Package :Export wooden
Fin material :Aluminun
Usage :Freezer
After Warranty Service :Online support
Local Service Location :None
Marketing Type :New Product 2023
After-sales Service Provided :Video technical support, Field installation, commissioning and training, No after-sales service, Online support
Port :Ningbo/Shanghai/Guangzhou
Conditon :New
more
Contact Now

Add to Cart

Find Similar Videos
View Product Description

Product name: Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

EF SERIES GROUND-TYPE BLAST FREEZER UNIT COOLERS

1. Product description:

EF series air cooler adopts floor type structure, which is mainly used for fast cooling processing or low temperature quick-freezing cold room.

● Casing:high quality galvanized steel with silver powder coating (RAL7001) , it has strong anti-corrosion property; The two sides plate adopt hinge structure, convenient and quick operation.

● Evaporator end plate adopts aluminum plate, effectively protect copper tube.

● Double water plate design: the outer water plate adopts angular structure, smooth drainage, no drainage dead angle; The inner water tray adopts the flume structure of aluminum plate. The condensed water or defrosted water is directly discharged into the outlet of the outer water tray through the inner water tray.

● The long air duct design with integral stretch arc has good air flow effect.

● Coil:copper pipe φ15, tube spacing 50×50 square arrangement, heat transfer area is large, heat transfer temperature difference is small, fin frosting speed is slow.

● Corrugated aluminum fins with hydrophilic film, fin spacing of 6.0, 9.0 and 12.0mm to meet the different requirements of cold room.

● Fan: operating temperature -45℃, blower type fan, equipped with more power, higher wind pressure motor, to ensure the external residual pressure, reduce the food surface wind speed, reduce dry consumption, improve the quality of frozen food.

● Defrosting:standard electric heating defrosting, stainless steel heating pipe are distributed on the coil tube fin and inner water plate, has a good defrosting effect. You can also choose hot gas defrost according to customer requirements.

● IP65 grade waterproof junction box and waterproof connector, the fan and heating pipe adopt independent wire box ,with better waterproof effect, high reliability.

● The outlet of the air cooler is equipped with schrader alve, which is convenient for users to detect pressure.

● Strict factory pressure test, test pressure 23bar.

● Expansion valve can be pre-installed according to customer requirements.

● It can meet refrigerant for R404A,R507A,R448A,R449A,R134a,R22 etc.

2. Standard configuration and options:

Parts Configuration Parts Configuration
Casing Al-Mg alloy sheet with powder coating × Defrosting Electric heating pipe
sheet with powder coating Water defrosting
Galvanized sheet with powder coating Hot gas
Stainless steel plate* Expansion valve

Fan

(blow)

WEIGUANG motor Drainpipe hot wire
EBM motor* Wind duct heating belt
The wind bucket motor
Suction type fan
Fin Aluminum fins
Hydrophilic aluminum fins

●:Standard;○:Options;×:Do not choose.

* : Use short side deflector air duct.

3. Technical data sheet:

3.1 Fin spacing 6.0mm

Model

Capacity/R404A

(KW)

Surface Tube volume Airflow Connection pipe Weight

Tc=0℃

ΔΤ=8K

Tc=-18℃

ΔΤ=7K

m2 dm3 m3/h Inlet Outlet Drain kg
EF632/DD-ET 26.6 21.3 106.8 20.6 26000 φ16 φ35 G2" 243
EF632/ED-ET 28.2 22.6 133.5 25.7 25000 φ22 φ42 G2" 254
EF632/FD-ET 30.4 24.3 160.2 30.9 24000 φ22 φ42 G2" 266
EF634/DD-ET 53.3 42.7 213.6 39.1 52000 φ22 φ42 G2" 373
EF634/ED-ET 56.7 45.4 267.0 48.9 50000 φ22 φ42 G2" 396
EF634/FD-ET 60.8 48.6 320.4 58.7 48000 φ28 φ54 G2" 418
EF636/DD-ET 80.0 64.0 320.4 57.7 78000 φ28 φ54 G2" 522
EF636/ED-ET 85.1 68.1 400.5 72.1 75000 2-φ22 2-φ42 G2" 555
EF636/FD-ET 91.3 73.0 480.6 86.5 72000 2-φ22 2-φ42 G2" 589
EF638/DD-ET 106.7 85.4 427.2 76.2 104000 2-φ22 2-φ42 G2" 670
EF638/ED-ET 113.4 90.7 534.0 95.3 100000 2-φ28 2-φ50 G2" 715
EF638/FD-ET 121.7 97.4 640.7 114.3 96000 2-φ28 2-φ50 G2" 760

3.2 Fin spacing 9.0mm

Model

Capacity/R404A

(KW)

Surface Tube volume Airflow Connection pipe Weight

Tc=0

ΔΤ=8K

Tc=-18℃

ΔΤ=7K

Tc=-25℃

ΔΤ=6K

m2 dm3 m3/h Inlet Outlet Drain kg
EF632/DJ-ET 19.1 15.3 12.6 73.1 20.6 27000 φ16 φ35 G2" 241
EF632/EJ-ET 22.8 18.3 15.0 91.4 25.7 26000 φ22 φ42 G2" 252
EF632/FJ-ET 25.3 20.2 16.7 109.6 30.9 25000 φ22 φ42 G2" 263
EF634/DJ-ET 38.3 30.7 25.2 146.2 39.1 54000 φ22 φ42 G2" 369
EF634/EJ-ET 45.6 36.5 30.0 182.7 48.9 52000 φ22 φ42 G2" 391
EF634/FJ-ET 50.6 40.5 33.3 219.3 58.7 50000 φ28 φ54 G2" 412
EF636/DJ-ET 57.5 46.0 37.9 219.3 57.7 81000 φ28 φ54 G2" 516
EF636/EJ-ET 68.5 54.8 45.2 274.1 72.1 78000 2-φ22 2-φ42 G2" 548
EF636/FJ-ET 76.0 60.8 50.1 328.9 86.5 75000 2-φ22 2-φ42 G2" 580
EF638/DJ-ET 76.7 61.4 50.6 292.4 76.2 108000 2-φ22 2-φ42 G2" 663
EF638/EJ-ET 91.3 73.1 60.2 365.5 95.3 104000 2-φ28 2-φ50 G2" 705
EF638/FJ-ET 101.3 81.1 66.8 438.6 114.3 100000 2-φ28 2-φ50 G2" 748

3.3 Fin spacing 12.0mm

Model

Capacity/R404A

(KW)

Surface Tube volume Airflow Connection pipe Weight

Tc=0

ΔΤ=8K

Tc=-18℃

ΔΤ=7K

Tc=-35℃

ΔΤ=6K

m2 dm3 m3/h Inlet Outlet Drain kg
EF632/DK-ET 16.1 12.9 10.4 56.2 20.6 27500 φ16 φ35 G2" 242
EF632/EK-ET 19.2 15.4 12.5 70.3 25.7 26600 φ22 φ42 G2" 253
EF632/FK-ET 21.0 16.8 13.6 84.4 30.9 25600 φ22 φ42 G2" 265
EF634/DK-ET 32.2 25.8 20.9 112.5 39.1 55000 φ22 φ42 G2" 372
EF634/EK-ET 38.6 30.9 25.1 140.6 48.9 53200 φ22 φ42 G2" 394
EF634/FK-ET 42.1 33.7 27.4 168.7 58.7 51200 φ28 φ54 G2" 416
EF636/DK-ET 48.5 38.8 31.5 168.7 57.7 82500 φ28 φ54 G2" 520
EF636/EK-ET 57.8 46.3 37.5 210.9 72.1 79800 2-φ22 2-φ42 G2" 553
EF636/FK-ET 63.2 50.6 41.0 253.1 86.5 76800 2-φ22 2-φ42 G2" 586
EF638/DK-ET 64.6 51.7 42.0 225.0 76.2 110000 2-φ22 2-φ42 G2" 667
EF638/EK-ET 77.2 61.8 50.1 281.2 95.3 106400 2-φ28 2-φ50 G2" 711
EF638/FK-ET 84.4 67.5 54.8 337.5 114.3 102400 2-φ28 2-φ50 G2" 755

1. In the table ,Tc is cold room temperature, ΔΤ is difference between cold room temp. and evaporation temp.

2. For cooling capacity of other working conditions, please refer to the correction coefficient.

4. Electrical parameter table:

Model Fan motor Electric defrosting
Voltage(V) Power(W) Current(A) Speed(r/min) Coil(KW) Tray(KW) Total(KW)
EF632/D* 380-3 2900 5.8 1390 12×0.8 2×0.8 11.2
EF632/E* 380-3 2900 5.8 1390 16×0.8 2×0.8 14.4
EF632/F* 380-3 2900 5.8 1390 16×0.8 2×0.8 14.4
EF634/D* 380-3 5800 11.6 1390 12×1.6 2×1.6 22.4
EF634/E* 380-3 5800 11.6 1390 16×1.6 2×1.6 28.8
EF634/F* 380-3 5800 11.6 1390 16×1.6 2×1.6 28.8
EF636/D* 380-3 8700 17.4 1390 12×2.3 2×2.3 32.2
EF636/E* 380-3 8700 17.4 1390 16×2.3 2×2.3 41.4
EF636/F* 380-3 8700 17.4 1390 16×2.3 2×2.3 41.4
EF638/D* 380-3 11600 23.2 1390 12×3.0 2×3.0 42.0
EF638/E* 380-3 11600 23.2 1390 16×3.0 2×3.0 54.0
EF638/F* 380-3 11600 23.2 1390 16×3.0 2×3.0 54.0

5.How to select correct evaparator:

Generally,Choose evaporator capacity=cold room cooling capacity *1.15

1.When the cold room temperature is around 0℃, select 4.5mm as fin space.

Evaporator choose=1.0*Q0

2.When the cold room temperature is around -18℃, select 6mm as fin space.

Evaparator choose=1.1*Q0

3.When the cold room temperature is around -25℃, select 9mm as fin space.

Evaparator choose=1.27*Q0

Remarks: The water defrost and hot gas defrost type are also optional.

Customized specification leave me message for details.

6.Want to know other related products?-click picture for detailed specification

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

7.How to assure quality? Any procedure?

Our QC department will make sure of each step

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

8.Do you factory?
We are factory established in 1995 and through 28years developed,welcomed by all our customers.Because of all your support now we are a big family of more than 300 people,covered 50000 square meters,and your supporting is very important of continuing our dream of eating fresh and healthy food.

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

9.Do you attend exhibition?

Each year we will attend domestic national and foreign exhibition,also we will support our agent to attend exhibition,welcome to join us.

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

10.Why choose us

Professional:28 years focus one thing-refrigeration equipments

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

Material we use sufficient

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

Certificate:CE, ISO, and cetiifcate of producing special pressure equipment

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

11.Projects reference?

Blast Freezer Room Equipment Cooling Unit For Cold Room 1.2kw--114kw

12.FAQ

1, Q:Where is your factory address?

A:We are factory and located in refrigeration equipment producing base Shengzhou,Zhejiang province.

2, Q: What is your package?

A: Our package comply to custom require not include original wood.

3, Q:What is your MOQ?

A: Ordinary products can order from 1 set.

4, Q: Can you offer sample?

A: Yes,we can offer sample.and cost and delivery at your charge.

5, Q:I can't find products on your list?

A: Please contact me directly.

6,Q:How can i confirm your factory?

A: We have third party verified document of Bureau Veritas report,you can download in company page or leave me message to get.

Inquiry Cart 0